Installation requirements for AC non redundant configurations 
For systems not requiring AC redundancy, the power supply subsystem can be 
installed with up to 4 PSUs. The PSUs can be connected to a single or multiple 
AC sources.
Three power supply modules are capable of handling the maximum power 
requirements for a fully configured PRIMERGY RX600 S5 server system, which 
include the following:
Four processors
1024 GB of memory
Eleven PCIe add-in cards (including the SAS/SATA RAID controller card) 
Eight hard disk drives
One optical drive
One tape drive
The hot swap feature allows the user to replace a failed power supply module 
without affecting the system functionality.
PSU Configuration
Max. DC Loading
DC Redundancy
1+1 (2 PSUs)
830W
Yes
2+1 (3 PSUs)
1580W
Yes
3+1 (4 PSUs)
2320W
Yes
Table 3: Maximum DC Loading Requirements