DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-277
status health 
8
status health
This command displays the current system alarm summary, maintenance busy 
summary, user summary, critical system status, and cabinet status. This same 
page displays with the 
monitor health
 command, except that the 
status health
 
output page does not update periodically.
Output
The following output example is a display of the 
status health
 command.
Percentage of Tests 
Aborted:
Percentage of aborted tests
Command:
Hardware-group action objects and qualifiers.
Test sequence:
Short or long.
Test repetition:
Displays continuously or the keyword repeats with the entered 
repeat value.
Output options:
Selections that were chosen on the input form: auto-page, 
background, or failures.
Hardware options:
Selections that were chosen on the input form: all-ports, or 
SPE-interchange.
Action/Object
Qualifier
Qualifier Description
Permissions
Defaults
Feature
Interactions
status health
print
Report prints to 
SAT-linked printer.
Examples:
status health
status health print
init
inads
craft
cust
nms
browse
none
High or Critical 
Reliability Systems = If 
standby SPE 
Emergency Transfer 
Select Switches change 
and handshakes are 
down, the displayed 
Emerg Trans field is 
incorrect until 
handshakes reactivate.
 
 status health
 SPE: A/Auto    B/functional               OCC:  ST:  9%   Cp: 25%  Sm: 10%  Idl:66%
 PNC: A-PNC/Auto B-PNC/functional   ALARM:Maj:  0   Min: 2  Wrn:  9
 Pwr: Comm   Sync:local   Logins:4   BUSYOUTS:Trk:  0   Stn:  0   Oth:  0
 Cab  EmTr  Mj  Mn  Wn  PNC  Cab  EmTr  Mj  Mn  PNC  Cab EmTr  Mj  Mn  Wn  PNC
 1    off   0|  7|  0   up
 2    off   0|  0|  4   up
 3    nia   0|  2|  0   up
                             -Press CANCEL to quit -   9:33 THU APR 16 :1993