Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-278
status health 
8
Field descriptions
Major
Number of logged major alarms. (0–200)
Minor
Number of logged minor alarms. (0–200)
Warning
Number of warnings logged in the alarm file. (0–200)
Trunks
Number of maintenance busied out trunks.
Stations
Number of maintenance busied out stations.
Others
Combined number of maintenance busied out objects excluding trunks 
and stations.
Static
Proportion of the CPU that is dedicated to high priority items (for 
example, the operating system). This percentage is rounded to the 
nearest integer, therefore a percentage of 0 means that the occupancy 
is less than one half of a percent.
SM
Proportion of the CPU that is dedicated to system management or 
periodic and scheduled maintenance. If many periodic or scheduled 
maintenance tests perform, this occupancy percentage can be high 
without affecting service. This percentage rounds to the nearest integer; 
therefore, a percentage of 0=the occupancy is less than one half of a 
percent (for example, an 89.6% occupancy displays as 90%).
CP
Proportion of the CPU that is dedicated to call processing. This 
occupancy has priority over SM and IDLE occupancy categories, and if 
needed, takes processor time from these occupancy categories. This 
percentage is rounded to the nearest integer.
Idle
Available proportion of the CPU. This percentage is rounded to the 
nearest integer.
Active SPE
A or B indicate the active processor complex. When the active 
processor complex is locked on-line with lock switching on DUPINT, the 
“lock” option displays; otherwise, “auto” displays.
Duplicated?
Duplication status of the SPE component. “y” = duplication; 
“n” = no duplication.
SPE Power
Power source for the processor complex. (commercial) When 
commercial power is unavailable, battery backup is in use and is 
indicated with “backup”.
Time Source
The current timing source. Display values for this field vary according to 
timing sources selected. “external” = For Stratum-3 hardware, “internal” 
= an internal source, such as a tone clock. 
Primary and secondary timing sources must be administered for the 
Stratum-4 option. “primary”= the primary administered source is in use, 
“secondary” = the administered secondary source is in use. “local” = 
neither the primary or secondary sources are in use.
# Logins
Number of current users.