Maintenance Commands and Trouble-Clearing Aids 
Page 8-279
status interface 
8
status interface
This command displays the number of counters maintained by the PI. (a front 
end processor implementing packet layers and link layers of the BX.25 protocol 
and the integrated services digital network (ISDN) procedure-D protocols.
Cab
Assigned cabinet number (1 to the highest system cabinet number).
Emerg Trans
Settings for emergency transfer switches on the maintenance board for 
each cabinet. Available options are: auto-on (“auto+” or “a+”), auto-off 
(“auto-” or “a-”), “on”, “off”, and “n.a.”. The system defaults to “auto+” or 
“auto-”. In this state, emergency transfer activate automatically if the 
cabinet fails (“+”=emergency transfer is activate, “-” = emergency 
transfer is inactive). “on” = emergency transfer automatically activates. 
“off” = the cabinet cannot activate emergency transfers. Duplicated 
SPEs systems = switch settings for both processors of the PPN (cabinet 
1) display. In this case, “auto+” is abbreviated “a+”, “auto-” is 
abbreviated “a-”, and “off” is abbreviated “of”. “on” does not change. 
“n.a.” = the emergency transfer switch setting is unavailable.
Mj
Number of major alarms associated with the cabinet. Asterisks are used 
to fill fields when numbers exceed 99. 
Mn
Number of minor alarms associated with the cabinet. Asterisks are used 
to fill fields when numbers exceed 99. 
Wn
Number of warnings associated with the cabinet. Asterisks are used to 
fill fields when numbers exceed 99. 
PNC
Port Network Connectivity (PNC) status for each port networks within a 
cabinet. When multiple port networks exist, Carriers A, B, and C are 
listed first and separated from Carriers D and E by a slash (for example, 
up/up). Availability of the Expansion Archangel Link (EAL) determines 
PNC status of a port network. “up” denotes that the EAL is available. 
“dn” denotes that the EAL is unavailable.
Time of Day
Current time of day acquired from the system.
Action/Object
Qualifier
Qualifier Description
Permissions
Defaults
Feature
Interactions
status 
interface
location
print
(cabinet-carrier-position) of the 
processor interface (PI board). 1 = 
the first processor interface in the 
carrier; 2 = the second processor 
interface in the carrier.
Report sent to printer.
Examples:
status interface a1
status interface 01a2
status interface 01b1
status interface b2
status interface b2 print
init
inads
craft
cust
rcust
bcms
browse
1 (one)
none