status station
8
Output
The following example shows the output for the
status sp-link
command.
Field descriptions
status station
This command displays the internal software state information for diagnosis and
to help locate the facilities to which the station is communicating.
to help locate the facilities to which the station is communicating.
Link State:
Operational mode of the link:
up
: the link is administered and a call is setup between the switch
and the system printer.
down
: the link is administered, but a call is not setup between the
switch and the system printer.
extension not administered
: the link (no system printer
extension) is not administered
Number of
Retries:
Number of times the switch has tried to set up the link since a
request to set up the link was received (1-999); if more than 999
retries have occurred,
request to set up the link was received (1-999); if more than 999
retries have occurred,
999
still displays. (This field displays only if
the
Link State:
field is
down
.)
Maintenance
Busy?
Whether any maintenance testing is being performed on the
system printer link:
system printer link:
yes
and
no
: system printer link is administered
blank: system printer link is not administered.
Action/
Object
Object
Qualifier
Qualifier Description
Permissions
Defaults
Feature
Interactions
Interactions
status
station
station
extension
print
Station extension (per dial-plan)
Report sent to printer
Examples:
status station 10020
status station 83277
status station 83277 print
status station 83277
status station 83277 print
init
inads
craft
cust
browse
inads
craft
cust
browse
none
none
status sp-link SPE A
SYSTEM PRINTER LINK STATUS
Link State: up
Number of Retries:
Maintenance Busy? no
Number of Retries:
Maintenance Busy? no