DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-174
BRI-PORT (ISDN-BRI Port), ABRI-PORT (ASAI ISDN-BRI Port) 
10
Layer 1 Transmission Error Counter Test (#624)
This test reads and clears the BRI port’s Layer 1 Transmission error counter 
maintained on the BRI-LINE circuit pack. This counter is incremented by the 
circuit pack when it detects a Layer 1 transmission problem. The test passes if 
the value of the counter is 0 (that is, the error is cleared). If the counter is not 
zero, the test fails, and the value of the counter is displayed in the Error Code 
field.
This error is most likely due to a problem with the wiring or the endpoint or 
adjunct (verify that the wiring meets the configuration rules defined in 
DEFINITY 
Communications System Generic 1 and Generic 3i Wiring
, 555-204-111). It does 
2012
ABORT
Internal System Error.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at one-minute intervals a maximum of five 
times.
2. If the test continues to abort, escalate the problem.
1
FAIL
The BRI-LINE circuit pack reports that it has detected an overcurrent 
condition and has turned off the EPF.
1. As necessary, check and repair the wiring between the circuit pack 
and the endpoint or adjunct. Check the endpoints and replace one 
or both sets if the sets are drawing too much current. Execute the 
test port PCSSpp
 command and review the results of the EPF 
Inquiry Test to verify the repair. If this test is still failing, proceed to 
Step 2.
2. Execute the 
test port PCSSpp
 command, and review the results of 
the Level 1 Status Inquiry Test. If this test is also failing, then follow 
the repair procedure for the Level 1 Status Inquiry Test. Otherwise, 
escalate this problem to the next tier.
PASS
The Electronic Power Feed Inquiry Test reports that the EPF is on.
2000
ABORT
Response to the test was not received from the circuit pack within the 
allowable time period.
1. If the test aborts repeatedly a maximum of five times, reset the 
circuit pack via the 
busyout board PCSS
 and 
reset board PCSS
 
commands.
2. If the test aborts again, replace the circuit pack.
2012
ABORT
Internal System Error.
Table 10-61.
TEST #622 Electronic Power Feed Inquiry  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page