DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-176
BRI-PORT (ISDN-BRI Port), ABRI-PORT (ASAI ISDN-BRI Port) 
10
This error can occur if signaling frames are being received from the Packet Bus 
at a rate sufficient to overflow the receive buffers on the circuit pack for a port OR 
if a hardware fault is causing the receive buffers not to be emptied properly by 
the circuit pack. This test is useful for verifying the repair of the problem.
Clear Error Counters Test (#270)
This test is not an actual test in the strict sense of the word. There are various 
error counters associated with each 
BRI-PORT/ABRI-PORT/ATT-PORT/LGATE-PT/ATTE-PT. This test clears those 
counters and triggers the auditing of Terminal Endpoint Identifier (TEI) values 
and layer 3 reinitialization. This test is used only to send messages to the 
BRI-PORT/ABRI-PORT/ATT-PORT/LGATE-PT/ATTE-PT and, therefore, should 
neither abort nor fail.
Table 10-63.
TEST #625 Receive FIFO Overflow Error Counter Test 
Error 
Code
Test 
Result
Description/ Recommendation
2000
ABORT
Response to the test was not received from the circuit pack within the 
allowable time period.
1. If the test aborts repeatedly a maximum of five times, reset the 
circuit pack via the 
busyout board PCSS
 and 
reset board PCSS
 
commands.
2. If the test aborts again, replace the circuit pack.
2012
ABORT
Internal System Error.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at one-minute intervals a maximum of five 
times.
2. If the test continues to fail, escalate the problem.
value
FAIL
The BRI-LINE circuit pack is still detecting errors of this type. The Error 
Code field contains the value of this counter.
1. Retry the command at one-minute intervals a maximum of five 
times.
2. If the test continues to fail, run the Long Test Sequence and pay 
particular attention to the Loop Around Tests (#618 and #619). See 
the repair procedures for the executed test if it fails. Otherwise, go 
to the next step.
3. Replace the circuit pack.
PASS
The Receive FIFO Overflow error counter was read correctly and has a 
value of 0.
Continued on next page