Lucent Technologies lucent ユーザーズマニュアル
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-277
CLSFY-BD (Call Classifier Circuit Pack)
10
CLSFY-BD (Call Classifier Circuit
Pack)
Pack)
Refer to XXX-BD (Common Port Circuit Pack) Maintenance documentation for
circuit pack level errors. See also Call Classifier Port (CLSFY-PT) Maintenance
documentation for related port information.
circuit pack level errors. See also Call Classifier Port (CLSFY-PT) Maintenance
documentation for related port information.
1.
Where P is the port network number (1 for PPN and 2 or 3 for EPN); C is the carrier
designation (for example, A, B, C, D, or E); and SS is the address of the slot in the carrier
where the circuit pack is located (for example, 01, 02, ..., etc.).
designation (for example, A, B, C, D, or E); and SS is the address of the slot in the carrier
where the circuit pack is located (for example, 01, 02, ..., etc.).
MO Name (in
Alarm Log)
Alarm
Level
Initial Command to
Run
1
Full Name of MO
CLSFY-BD
MIN
test board PCSS sh
Call Classifier Circuit Pack
CLSFY-BD
WRN
test board PCSS sh
Call Classifier Circuit Pack