Lucent Technologies lucent ユーザーズマニュアル
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-278
CLSFY-PT (Call Classifier Port)
10
CLSFY-PT (Call Classifier Port)
The TN744 Call Classifier (CLSFY-BD) circuit pack is a service circuit pack that
enables usage of the Outbound Call Management (OCM) and the Inbound Call
Management (ICM) features. On a G3iV2-386 system, the TN744 also enables
usage of R2-MFC signaling for incoming and outgoing feature operation. There
are eight ports (CLSFY-PTs) on the Call Classifier circuit pack. Each port can
handle call classification, touch-tone reception, or, for G3iV2-386 systems, MFC
tone generation and detection or touch-tone reception.
enables usage of the Outbound Call Management (OCM) and the Inbound Call
Management (ICM) features. On a G3iV2-386 system, the TN744 also enables
usage of R2-MFC signaling for incoming and outgoing feature operation. There
are eight ports (CLSFY-PTs) on the Call Classifier circuit pack. Each port can
handle call classification, touch-tone reception, or, for G3iV2-386 systems, MFC
tone generation and detection or touch-tone reception.
The CLSFY-PT maintenance feature defines a set of tests to ensure that the Call
Classifier circuit pack ports are capable of detecting tones for call classification,
and detecting and generating necessary tones for correct MFC feature
operation.
Classifier circuit pack ports are capable of detecting tones for call classification,
and detecting and generating necessary tones for correct MFC feature
operation.
Hardware Error Log Entries and Test to Clear
Values
Values
1.
Where P is the port network number (1 for PPN and 2 or 3 for EPN); C is the carrier designation (e.g.,
A, B, C, D, or E); SS is the address of the slot in the carrier where the circuit pack is located (e.g.,
01, 02, ..., etc.); and pp is the 2-digit port number (e.g.., 01).
A, B, C, D, or E); SS is the address of the slot in the carrier where the circuit pack is located (e.g.,
01, 02, ..., etc.); and pp is the 2-digit port number (e.g.., 01).
MO Name (in
Alarm Log)
Alarm
Level
Initial Command to Run
1
Full Name of MO
CLSFY-PT(a)
MAJOR
test port PCSSpp sh
Call Classifier Port Maintenance
CLSFY-PT
MINOR
test port PCSSpp sh
Call Classifier Port Maintenance
CLSFY-PT
WARNING
release port PCSSpp
Call Classifier Port Maintenance
Table 10-91.
Call Classifier Port (CLSFY-PT) Error Log Entries
Error
Type
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
1
any
Tone Detector
Audit/Update Test
(#43)
Audit/Update Test
(#43)
MAJOR/
MINOR (a)
MINOR (a)
ON
test port PCSSpp r 2
18
Port has been
busied out by
system technician
busied out by
system technician
WARNING
OFF
release port PCSSpp
257 (b)
17666
Test (#43)
MAJOR/
MINOR(a)
MINOR(a)
ON
test port PCSSpp r 3
Continued on next page