Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-279
CLSFY-PT (Call Classifier Port) 
10
Notes:
a. There are two possible alarm levels for this error type: major alarm and 
minor alarm. A major alarm is raised if the total number of call classifier 
ports currently in-service is less than or equal to 1/2 of the administered 
threshold number. Otherwise, a minor alarm is raised. In either case, run 
the short test sequence against the port and follow the error code 
procedures for the individual tests.
The threshold number of call classifier ports for service is administered 
using the 
change system-parameters maintenance
 command. For 
details, refer to Chapter 5, "Routine Maintenance Procedures".
b. The call classifier port lost its translation. Testing the call classifier port is 
sufficient to reload its translation. If testing the call classifier port does not 
clear the error, then the call classifier circuit pack containing the defective 
call classifier port should be replaced.
c. This error indicates the call classifier port is having problems detecting 
system tones (DTMF, etc.) or detecting and generating necessary 
R2-MFC tones. This error should accompany some percentage of failed 
calls. If this error type is persistently logged, then the call classifier circuit 
pack containing the defective call classifier port should be replaced.
System Technician-Demanded Tests: 
Descriptions and Error Codes
Always investigate tests in the order presented in the following tables when 
inspecting errors in the system. By clearing error codes associated with the 
Tone 
Detection Verification Test
, for example, you may also clear errors generated 
from other tests in the testing sequence.
513 (c)
any
Tone Detection 
Verification Test 
(#42)
MAJOR/ 
MINOR (a)
ON
test port PCSSpp r 3
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
Tone Detection Verification Test (#42)
X
X
ND
Tone Detection Audit/Update Test (#43)
X
X
ND
Table 10-91.
Call Classifier Port (CLSFY-PT) Error Log Entries  — 
Continued
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
Continued on next page