MAINTENANCE
NOTE:  The information contained in this Manual is designed to assist you in the safe maintenance of the Nailer.
 
Some illustrations in this Manual may show details or attachments that diff er from those on your own Nailer.
MAINTENANCE AND INSPECTION
Read section titled “SAFETY” (pages 4 – 7).
 WARNING
● Disconnect air hose and remove all nails 
from Nailer when:
1)  doing maintenance and inspection; and 
2)  clearing a jam.
1.  Clearing a jam
 
Remove a jammed nail in the following order:
1
 DISCONNECT AIR HOSE.
2
 Open the nail guide.
3
 Insert a rod into the outlet.
  Tap the rod with a hammer.
Hammer
Rod
Outlet
Disconnect 
air hose
1
4
 Remove the jammed nail with a slotted screw 
driver.
Nail
Slotted Screw Driver
5
 Cut the deformed collated wire with nippers.
  Correct the deformation.
6
 In case of frequent jam, contact a Hitachi 
authorized service center.
2.  Inspecting the push lever
1
 DISCONNECT AIR HOSE.
2
 Clean the push lever sliding part.
  Lubricate it with Hitachi pneumatic tool lubricant. 
Lubricate
Disconnect 
air hose
1
3.  Inspecting the feeders
1
 DISCONNECT AIR HOSE.
2
 Clean the knob sliding part.
  Lubricate it with Hitachi pneumatic tool lubricant.
Nail 
Guide
Knob
Push Lever
Disconnect 
air hose
1
3
 Open the nail guide and remove dust.
  Lubricate the sliding groove of the feeder and 
shafts.
Nail Guide
Main Nail Stopper
Feeder
Feeder Shaft
Nose Opening
Sub Nail Stopper