Graco 3A0869J ユーザーズマニュアル

ページ / 80
Basic Operation
3A0869J
35
8. If the system is not completely clean, repeat step 6.
NOTE: If necessary, adjust purge sequence times 
so only one cycle is required.
9. Trigger the gun to relieve pressure. Engage trigger 
lock.
10. If spray tip was removed, reinstall it.
11. Adjust the solvent supply regulator back to its nor-
mal operating pressure.
NOTE: The system remains full of solvent.
NOTE: If your system uses 2 guns, you must trigger 
both guns simultaneously during a purge to purge both 
guns and lines. Verify that clean solvent flows from each 
gun. If not, repeat purge or clear clog/blockage in sys-
tem.
Color Change
Color Change Sequence
Step 1. Color Purge. The system flushes out the color 
with solvent. The selected color change solvent valve 
opens during Purge Time and closes when the time 
expires.
Step 2. Catalyst Purge. The system flushes out the 
catalyst with solvent. The catalyst change solvent valve 
opens during Purge Time and closes when the time 
expires.
Step 3. Final Purge. The system fills the line with the 
selected purge media (usually solvent). The selected 
purge valve opens during the Final Purge Time and 
closes when the time expires.
Step 4. Catalyst Fill. The system fills the line with new 
catalyst. The new catalyst valve opens during the Fill 
Time and closes when the fill volume is reached.
Step 5. Color Fill. The system fills the line with new 
color. The new color valve opens during the Fill Time 
and closes when the fill volume is reached.
Step 6. Mixed Material Fill. The system fills the line 
with mixed material. The system begins mixing compo-
nents A and B until the fill volume expires.
Color Change Procedures
1. Place the gun in the gun flush box if used, and close 
the lid.
2. Press 
 on Run Mix Spray (Screen 2) or 
 
from any screen to put the system in Standby.
3. Use the scroll keys, 
 
or
 
to select the new 
color. Press 
 
to begin the color change 
sequence.
4. If a gun flush box is not used, trigger 
the gun into a grounded metal pail 
until the color change sequence is 
complete. If your system has two 
guns, trigger both guns at the same 
time.
NOTE: The color change timer does not start until 
the gun is triggered and fluid flow is detected. If no 
flow is detected within 2 minutes, the color change 
operation aborts. The Display Module enters 
Standby 
 mode at the previous color.
Error SG occurs if the gun flush box is open.
Error SAD1 or SAD2 occurs if the AFS is on.
5. Trigger the gun (or guns) while the system flushes 
the current color, purges with solvent, and loads the 
new color.
NOTE: If your system uses 2 guns, you must trigger 
both guns simultaneously during the entire color purge, 
solvent purge, and load color sequence.
NOTE: If you do not see clear solvent flow, the system 
did not flush successfully. Stop the color change. Look 
for a clog in the line or increase the flush time.
6. During color change, the Recipe icon blinks on and 
off, and you’ll see the number of the current color 
and the new color. When the color change is com-
plete, Standby is highlighted.
7. When you are ready to spray, remove the gun from 
the gun flush box if used, and close its door. 
NOTE: The gun flush box door must be closed for 
the atomizing air valve to open.
8. Press 
 to start spraying.