Basic Operation 
34
3A0869J
3. Adjust the flow rate. The fluid flow rate shown on the 
Display Module screen is for either component A or 
B, depending on which dose valve is open.
.
If the fluid flow rate is too low: increase air pres-
sure to component A and B fluid supplies or 
increase the regulated fluid pressure of mixed 
material.
If the fluid flow rate is too high: reduce the air 
pressure to component A and B fluid supplies, 
close the dose valves further, or decrease the reg-
ulated fluid pressure of mixed material.
4. Turn on atomizing air to the gun. Check the spray 
pattern as instructed in your spray gun manual.
NOTE: 
Pressure adjustments of each component will vary 
with fluid viscosity. Start with the same fluid pres-
sure for component A and B, then adjust as needed.
Do not use the first 4-5 oz. (120-150 cc) of material 
as it may not be thoroughly mixed due to errors 
while priming the system.
Purging
NOTE: SeRun Mode Details, pages 42-43, for further 
screen information, if needed.
Purge the system:
at the end of potlife
breaks in spraying that exceed the potlife
overnight shutdown or end of shift
the first time material is loaded into equipment
servicing
shutting down equipment for an extended period of 
time
1. Press 
 on Run Mix Spray (Screen 2) or 
 
from any screen to put the system in Standby.
2. Trigger the gun to relieve pressure.
3. If you are using a high pressure gun, engage the 
trigger lock. Remove spray tip and clean tip sepa-
rately.
4. If using an electrostatic gun shut off the electrostat-
ics before flushing the gun.
5. Set the solvent supply pressure regulator at a pres-
sure high enough to completely purge the system in 
a reasonable amount of time but low enough to 
avoid splashing or an injection injury. Generally, a 
setting of 100 psi (0.7 MPa, 7 bar) is sufficient.
6. If using a gun flush box, place the gun into the box 
and close the lid.
7. Press 
 on Run Mix Spray (Screen 2). The 
purge sequence automatically starts. 
If the gun flush box is not used, trig-
ger the gun into a grounded metal 
pail until the purge sequence is com-
plete.
When done purging, the system automatically 
switches to Standby mode.
F
IG
. 21. Flow Rate Display
NOTICE
Do not allow a fluid supply tank to run empty. It is pos-
sible for air flow in the supply line to turn gear meters 
in the same manner as fluid. This can damage the 
meters and lead to the proportioning of fluid and air 
that meets the ratio and tolerance settings of the 
equipment. This can further result in spraying
uncatalyzed or poorly catalyzed material.
Flow
rate
Active
recipe