Basic Operation
3A0869J
33
4. Press 
 to move to Calibration 2 (Screen 23).
5. Press 
to highlight the meter you wish to cali-
brate. Press 
. An X displays in the box.
6. Press 
 to start the calibration on the checked 
meter (A with fluid A1, A2, or A3, or B). Press 
 
to cancel the calibration.
7. Trigger gun into a graduated cylinder. Dispense a 
minimum of 200-300cc of material.
NOTE: Stop triggering the gun when desired amount is 
reached. Do not press 
, as it will cancel the calibra-
tion.
8. The volume that the ProMix 2KE measured displays 
on the Display Module.
9. Compare the amount on the Display Module to the 
amount in the graduated cylinder.
NOTE: For maximum accuracy, use a gravimetric 
(mass) method to determine the actual volumes dis-
pensed.
If the screen and actual volumes are different, press 
to highlight the dispense volume field. Press 
. Press 
to move between digits. Press 
 to change a digit. Press 
when field is 
correct. 
NOTE: If the value is substantially different, repeat the 
calibration process until the dispensed volume and mea-
sured volume match.
10. After the volume for A1 (A2, A3) or B is entered, the 
ProMix 2KE controller calculates the new k-factor 
and shows it on Calibration 1 (Screen 22) and Cali-
bration 2 (Screen 23).
11. Before you begin production, clear the system of 
solvent and prime it with material. 
a. Go to Mix mode.
b. Trigger the gun into a grounded metal pail until 
mixed material flows from the gun nozzle.
Spraying
NOTE: SeRun Mode Details, pages 42-43, for further 
screen information, if needed.
1. Calibrate the meters as described in Meter Calibra-
tion, page 32. Meter k-factors will update automati-
cally based on calibration results. Make additional 
manual changes, if desired, as described in Cali-
bration 1 and 2 (Screens 22 and 23)
, page 49.
2. Press 
 . The system will load the correct potlife 
volume based on hose length and diameter entered 
on Configure 2 (Screen 19). Once material is 
loaded, the system returns to Standby. Press 
 
again to spray the active recipe.
F
IG
. 20. Dispensed Volume Comparison
Volume measured 
by system displays 
here.
Enter dispensed 
volume here.