Champion pp-3 ユーザーズマニュアル

ページ / 67
C O N T R O L   P A N E L S  
 
Sanitize Heater Temperature 
This setting sets the water temperature for the Sanitize tank. 
Parameter name: H E A T E R   2   T E M P E R A T U R E  
Allowed values: O F F , and 1 0 0 e  to 2 0 0 e  (3 8
d
 to 9 3
d
Factory default: O F F  
Buzzer Time 
This is the time the buzzer will sound when a wash cycle is over. 
Parameter name: B U Z Z E R   T I M E  
Allowed values: 0 : 0 0  to 9 . 5 9  
Factory default: 0 : 1 0  
Key Press Buzzer Volume 
When a key is pressed, the buzzer can beep for feedback.  The volume of this feedback is 
adjustable.  Note that this does not affect the alarms and other sounds, which remain at 
100% volume. 
Parameter name: B U Z Z E R   V O L U M E  
Allowed values: 0  (no sound) to 4   (loudest) 
Factory default: 4  
 
Dry Fire Period 
The heater is not used at 100% when trying to detect a dry fire in the OFF state.  This 
parameter (along with the next one that follows) allows fine-tuning of the heater power.  
The period is the time over which the duty cycle is calculated. 
Parameter name: D R Y   F I R E   P E R I O D  
Allowed values: 1 0  to 1 0 0 0  Milliseconds 
Factory default: 7 0 0  
 
Dry Fire Duty 
The heater is not used at 100% when trying to detect a dry fire.  This parameter determines 
the duty cycle used. 
Parameter name: D R Y   F I R E   D U T Y  
Allowed values: 1  to 1 0 0  % 
Factory default: 6 5  
40