Aethra d2061 ユーザーズマニュアル

ページ / 122
USER’S MANUAL 
                                                                                ADSL TESTER D2061 
 
3.5.2.  Running an ATM Ping test 
 
In order to obtain correct data, the remote device must be 
enabled for managing the OAM maintenance cells. 
When you have defined the setup for testing, continue as follows: 
 
Select ‘Use this setup for testing’.  
 
Connect the instrument as displayed on the screen and 
press the RIGHT CURSOR key.  
 
Start the ATM Ping test. 
The test results displayed are the following: 
► 
Ping status 
► 
Round Trip Delay 
► 
Errors (missed cell, time) 
If the ADSL connection is down, first of all the D2061 tries to make up the link with 
the ATU-C. 
 
If it’s not possible to open the ADSL connection, the PING test 
fails. 
 
 
 
CHAPTER 3 - PERFORMING A MANUAL TEST 
39