L3 (bearer services): Setup AUTOMATIC to enable automatic test of the bearer and 
teleservices capability of the access (Speech, Data, Fax Gr.4,…), or choose the 
service to test 
Supplementary services: Choose AUTOMATIC to enable automatic test of the 
supplementary services available on the access (CLIP, DDI, CF, …), or choose the 
service to test 
B channel check: Choose AUTOMATIC to enable automatic test of the B channels 
availability, or choose the channel to test 
2.3.2.  Running an automatic access test 
When you have defined the setup for the automatic test, continue as follows:    
 
Select ‘Use this setup for testing’ in the first SETUP page.  
 
Connect the instrument as displayed on the screen and 
press the right cursor key. 
 
Start the automatic test. The test results appear on the 
screen.   
Note that: 
The START key changes to STOP. Use it to stop the test. 
To obtain the access configuration, the instrument places a series of calls to the 
entered number, changing the profile and the B channel every time, and tries to verify 
the supplementary services. 
Following, are some examples of a full sequence test “RESULT: ACCESS TEST” 
screens: 
 
 
CHAPTER 2 - PERFORMING AN AUTOMATIC TEST 