4.
Use Maximum Advertise Interval to enter the maximum time (in seconds) allowed
between router advertisements sent from the interface.
5.
Use Minimum Advertise Interval to enter the minimum time (in seconds) allowed between
router advertisements sent from the interface. The value must be in the range of (3 to 1800).
Default value is 450.000000.
6.
Use Advertise Lifetime to enter the value (in seconds) to be used as the lifetime field in
router advertisements sent from the interface. This is the maximum length of time that the
advertised addresses are to be considered as valid router addresses by hosts.
7.
Use Preference Level to specify the preference level of the router as a default router
relative to other routers on the same subnet. Higher numbered addresses are preferred. You
must enter an integer.
8.
Use Cancel to cancel the configuration on the screen and reset the data on the screen to
the latest value of the switch.
9.
Use Apply to send the updated configuration to the switch. Configuration changes take
effect immediately.
Virtual Router Redundancy Protocol
The Routing > VRRP tab contains links to the following web pages that you use to configure
and display Virtual Router Redundancy Protocol (VRRP) data:
and display Virtual Router Redundancy Protocol (VRRP) data:
•
•
Basic VRRP Configuration
To display the Basic VRRP Configuration page, click Routing > VRRP > Basic > VRRP
Configuration
Configuration
. The following page is displayed.
Configure the global VRRP settings.
1.
In the Global Configuration Admin Mode field, set the administrative status of VRRP in
the router to either Enable or Disable option. By default, VRRP is disabled.
2.
The VRID field is only configurable if you are creating a new virtual router. Enter the VRID.
Valid values are 1 to 255.