6.  Install the lower duct cover (rear) to the range hood canopy. 
Spread the lower duct cover opening slightly and position it 
over the upper duct cover. Set the lower duct cover in place. 
Position so the flanges of the lower duct cover set into the 
flanges of the upper duct cover. Make sure the front and 
rear lower duct covers mate properly.
NOTE: When assembling the rear lower duct cover to the front 
lower duct cover, the flange (both sides) must be placed over 
the plastic clip to secure the lower duct covers together at 
the bottom.
7.  Secure the lower duct covers together at the top using 
2 plastic clips. Use one plastic clip on each side.
8.  Secure the lower duct cover to the range hood canopy 
using 4 - 4.2 x 8 mm screws.
Complete Installation
1.  For non-vented (recirculating) installations only, install 
charcoal filters over metal grease filter. See the “Range 
Hood Care” section.
2.  Install metal filters. See the “Range Hood Care” section.
3.  Check the operation of the range hood blower and light. 
See the “Range Hood Use” section.
If range hood does not operate, check to see whether a 
circuit breaker has tripped or a household fuse has blown. 
NOTE: To get the most efficient use from your new range hood, 
read the “Range Hood Use” section.
A
B
D
C
A.  Lower duct cover (rear)
B.  Plastic clips
C.  Lower duct covers
D.  Upper duct covers
A
B
A.  Plastic clips (2)
B.  Lower duct covers top clip area