Cisco Cisco Unified MeetingPlace Audio Server メンテナンスマニュアル

ページ / 313
5-20
Cisco MeetingPlace Audio Server 5.2 Customer Engineering Guide (for Cisco MeetingPlace 8106)
78-16411-01
Chapter 5      Repairing and Maintaining the 8106 Server
  Replacing T1 Smart Blades or Smart Blades
Step 2
Press the ejector levers outward. See 
Step 3
Holding the T1 Smart Blade or Smart Blade transition module by the levers, partially insert the transition 
module into the slot, about half way.
Step 4
Verify that the T1 Smart Blade or Smart Blade transition module is properly seated in the guides, left 
and right. If not, remove the transition module and try again.
Step 5
Pushing gently and firmly on the T1 Smart Blade or Smart Blade transition module’s face plate, slide the 
transition module into the slot until you encounter significant resistance. At this point, the levers should 
be in contact with the chassis rails so they will grab when pushed inward.
Step 6
Use the ejector levers to seat the T1 Smart Blade or Smart Blade transition module in the slot by closing 
the levers toward one another until they are in the horizontal locked position. See 
Step 7
Secure the T1 Smart Blade or Smart Blade transition module by tightening the captive screws on the left 
and right of the panel. See 
Step 8
Verify that any empty slots have covers on them.
Warning
Blank faceplates and cover panels serve three important functions: they prevent exposure to 
hazardous voltages and currents inside the chassis; they contain electromagnetic interference (EMI) 
that might disrupt other equipment; and they direct the flow of cooling air through the chassis. Do not 
operate the system unless all cards, faceplates, front covers, and rear covers are in place. 
Statement 
1029
Step 9
Attach the power cable to the back of the server.
Step 10
Power up the server. Refer to the 
Testing a T1 Smart Blade or Smart Blade card and transition module
Step 1
Verify the T1 Smart Blade or Smart Blade card’s ejector levers are locked. If the card is not locked, 
power down MeetingPlace as described in the 
 and 
reseat the card.
Step 2
Verify the T1 Smart Blade or Smart Blade transition module’s ejector levers are locked. If the transition 
module is not lockedpower down MeetingPlace as described in the 
 and reseat the transition module.
Step 3
Test the installation by following the procedure in the 
.