Problem:
In Layer 3 mode, SNTP Broadcast can only be operated from the CLI.
Solution:
There is no workaround.
Problem:
The EEE operational status should become disabled when Auto
Negotiation is disabled. (CQ132106)
Solution:
When the speed on a port is 1 Gigabit, auto negotiation has no effect on
the EEE functioning state.
Problem:
The Voice VLAN should be prevented from being set as Guest VLAN,
and the user should receive a warning. This is not happening. (CQ132684)
Solution:
Avoid setting the Voice VLAN as guest VLAN and vice-versa.
Problem:
When the Mrouter learning mode is changed between “user defined” to
“auto” and vice-versa, the IGMP Querier election process does not start.
(CQ132805)
(CQ132805)
Solution:
Disable IGMP Snooping and re-enable again, every time the Mrouter
learning mode is changed to start the Querier election process.
Problem:
Some WEB GUI pages require full version compatibility of JRE, Browser
and JRE-Browser applets. For XML compatibility reasons, MSXML DLL Version 6 is
required for IE browser users.
required for IE browser users.
Solution:
For download and installation information, refer to the following link:
Problem:
Notification Recipients table entry becomes un-editable with an
incorrect or missing parameter. (CQ133316)
Solution:
There will be an asterisk by any values for a table entry which are
incorrect. This can be caused by the deletion of users, views, etc. If any of these
values are incorrect, then the entry will be un-editable. First add the missing user,
view, and so on, in order to edit the entry. The delete button still works regardless
of whether the values are correct or not.
values are incorrect, then the entry will be un-editable. First add the missing user,
view, and so on, in order to edit the entry. The delete button still works regardless
of whether the values are correct or not.
Problem:
The result of cable length test for 100 meters is incorrect. It will show
between 110 to 140 meters. (CQ132941)
Solution:
There is no workaround.
Problem:
The maximum number of IPv6 ACEs that can be applied on an interface
is 244, not 512 as documented. The user receives the message “Cannot apply
because of a lack of hardware resources.” (CQ130161)
because of a lack of hardware resources.” (CQ130161)
Solution: