Cisco Cisco SG200-26P 26-port Gigabit PoE Smart Switch

ページ / 21
Release Notes for 200, 300, 500, and ESW2 Series Switches Firmware Version 1.4.0
19
Release Notes
Problem:
If changing the active image with the menu CLI, the active image after 
reboot field is not updated. If you change the image number and reboot, then the 
image does change, but the display in the menu CLI is incorrect. (CQ132211)
Solution:
There is no workaround.
Problem:
When using the CLI, any time that DNS is used, the user is blocked from 
interacting with the CLI until the DNS lookup has completed. (CQ133234)
Solution:
The user must wait until the DNS lookup has completed before issuing 
another command.
Problem:
Egress rate shaping does not work as expected. Configuring egress 
shape on Gigabit ports or on Combo ports between 64k to 5000k, will always 
result in 2 Million Bits. This is resolved with the new hardware release 1.1.1.8. It still 
exists on HW V01. It also does not work on SG300-52/52P & SG200-52/52P 
switches and all uplink ports of Sx500 and SG500X. (CQ123397 and CQ130715)
Solution:
There is no workaround.
Problem:
SNTP synchronization error messages are not logged when an 
incorrect MD5 key leads to the loss of synchronization. (CQ132636)
Solution:
There is no workaround for broadcast messages. For Unicast servers, 
in the SNTP server table the status message will either say “In process” or “Down” 
for those servers that have failed authentication.
Problem:
PoE ports on certain Nikola switches might not power the connected 
powered devices (PD) when used along with Cisco IP Phone 7960 with PID=68-
0808-xx. This issue impacts the following switch models: 
Switch SKUs: SG200-26P, SG200-50P, SG300-28P, SG500-28P, SG500-52P, 
SG500X-24P and SG500X-48P.
Solution:
Use CAT 5 cables with 2 pair pins 1, 2, 3, and 6.
Problem:
When configuring egress shaping rates on port 1, and enable flow 
control on port2, the whole vlan port egress rates will be the same. Flow control 
uses the whole buffer management scheme. When one port is configured to FC 
ALL ports are applied by the new scheme. QoS function on other ports will be 
effected also. (CQ144583)
Solution:
When using QoS, disable the flow control function.
Problem:
When managing a switch through the web-based interface, the loading 
time on some of the web pages can take a long time, approximately 3-10 seconds 
depending on the content in the tab. (CQ143850)
Solution:
Use the command line interface instead.