Release Notes for 200, 300, 500, and ESW2 Series Switches Firmware Version 1.4.0
Release Notes
Problem:
When managing stacking switches through the web-based interface, 
the loading time on the following web pages is more than 10 seconds: (CQ143851)
Status and Statistics
Port Management
VLAN Management
Access Control
Quality of Service
Solution:
Use the command line interface instead.
Problem:
If you modify an IPv6 tunnel configuration, the change will not take 
effect until you perform a shut then no shut on the tunnel interface. (CQ146071)
Solution:
You must perform a shut then no shut the tunnel interface for it to take 
effect.
Problem:
When a 10G DAC (Direct Attached Cable) is connected to the copper 
port of the SG500 using the last two ports (combo ports), the fiber link status 
display might be up even when the link is not active. 
Solution:
There is no workaround.
Problem:
When enabling IPv6 unicast-routing, the interface cannot get an ipv6 
address via auto-config. (CQ146156)
Solution:
Configure the interface using a static IPv6 address.
Japanese language files and firmware version compatibility 
guideline
Users will see a mismatch in the features between the English language and the 
Japanese language when running certain combinations of firmware and language 
files. Users will see new features added since version 1.1.1.6 in English instead of 
Japanese in the GUI when running firmware version 1.1.2.0 and higher subject to 
the following restriction:
Japanese language files version 1.1.1.6 and older are forward compatible 
up to Firmware version 1.1.2.0. For example: loading a version 1.1.1.6 
language file onto a device running firmware version 1.2.7.76 and up will fail.
Japanese language files version 1.1.1.10 and newer are only compatible 
with firmware version 1.2.7.76 and newer.