No Forward RF Signal 
 
89 
 
No Forward RF Signal 
The forward RF signal can be measured at the line extender module forward input 
and forward output test points. 
 
No Forward RF Signal Troubleshooting Table 
Before you begin troubleshooting for no forward RF signal, verify that the line 
extender is receiving the proper forward RF input signal from the upstream 
equipment. 
Important: You cannot balance the line extender without the proper forward RF 
input signal. 
Possible cause 
Solution 
No forward RF signal at the forward 
input test point. 
 
Verify that the line extender is receiving the 
proper forward RF input signal from the 
upstream equipment. 
Important: You cannot balance the line 
extender without the proper forward RF input 
signal. 
There is forward RF signal at the 
forward input test point, but no 
signal at one or all of the forward 
output test points. 
 
Verify that the line extender module is 
receiving the proper AC and DC voltages. 
Refer to No AC Power (on page 85) and No DC 
Power
 (on page 87). 
 
Verify that all the proper accessories, pads, 
EQs, and signal directors (if applicable) are 
firmly installed in the correct locations. 
 
Verify that the factory installed accessories are 
firmly installed in the correct locations. 
Note: Verifying factory installations involves 
removing the line extender module cover. 
Reinstall the line extender module cover 
properly or RF signal degradation may result. 
 
Replace the line extender module.