Low or Degraded Forward RF Signal 
 
91 
 
Possible cause 
Solution 
There is a proper forward RF signal 
at the forward input test point, but a 
low or degraded signal at one or all 
of the forward output test points. 
 
Verify that the line extender module is 
receiving the proper DC voltages. Refer to No 
DC Power
 (on page 87). 
 
Verify that switch S1 is in the proper position 
for your line extender module configuration. 
Refer to Balancing and Setup (on page 41) for 
more information. 
 
Verify that all the proper accessories, pads, 
EQs, and signal directors (if applicable) are 
firmly installed in the correct locations. 
 
Verify that the factory installed accessories are 
firmly installed in the correct locations. 
Note: Verifying factory installations involves 
removing the line extender module cover. 
Reinstall the line extender module cover 
properly or RF signal degradation may result. 
 
Replace the line extender module.