Chapter 4        Troubleshooting 
 
 
 
90 
 
Low or Degraded Forward RF Signal 
The forward RF signal can be measured at the line extender module forward input 
and forward output test points. 
 
Low or Degraded Forward RF Signal Troubleshooting Table 
Before you begin troubleshooting for a low or degraded forward RF signal, verify 
that the line extender is receiving the proper forward RF input signal from the 
upstream equipment. 
Important: You cannot balance the line extender without the proper forward RF 
input signal. 
Make sure you have configured the line extender module according to the 
specifications in the design print, and that the line extender has warmed up for 
approximately one hour. 
Make sure you are using the proper tilt reference when setting levels. An 870 MHz, 1 
GHz or 1.2 GHz design balanced at 550 MHz requires a corrected tilt reference to 
compensate for the difference in carrier levels between 550 MHz and 870 MHz, 1 
GHz or 1.2 GHz. The tilt reference at 550 MHz is lower than the tilt reference at 870 
MHz, 1 GHz or 1.2 GHz. Refer to the tilt charts in Technical Information (on page 97) 
for more information. 
Important: If the line extender cover was ever removed, make sure it was properly 
reinstalled. Improperly reinstalling the line extender module cover may result in RF 
signal degradation. 
Possible cause 
Solution 
Low or degraded forward RF signal 
at the forward input test point. 
 
Verify that the line extender is receiving the 
proper forward RF input signal from the 
upstream equipment. 
Important: You cannot balance the line 
extender without the proper forward RF input 
signal.