Upgrading Existing Housing Seizures 
 
17 
 
 
3  Using a ½ in. nut driver, install the new seizure screws from the upgrade kit in 
the housing. 
4  Do one of the following as appropriate: 
 
If the coaxial cable is connected to the housing, tighten each seizure screw 
from 2 ft-lb to 5 ft-lb (2.7 Nm to 6.8 Nm). 
 
If the coaxial cable is not connected to the housing, proceed to To Connect the 
Coaxial Cable Pin Connector to the Node Housing
 (on page 24). 
5  Place the blue stickers on the outside of the housing between the ports to indicate 
that the upgrade has been completed.