Cisco Cisco 1 GHz GainMaker Amplifier インストールガイド
Chapter 3 Balancing and Setup
48
Bode Mode
Description
Note
Manual mode
Bode circuit is by-passed, the
bode functions are disabled.
bode functions are disabled.
You can only use the forward
path balancing procedure in
Forward Path Balancing for
Manual Stations (on page 73)
path balancing procedure in
Forward Path Balancing for
Manual Stations (on page 73)
To Select the Forward Path Balancing Procedure
Refer to the following table to direct you to the proper starting point to balance your
line extender using your preferred method.
line extender using your preferred method.
If you have ...
and you use ...
go to ...
a line extender configured
with AGC
with AGC
manual mode for balancing
a line extender configured
with AGC
with AGC
thermal setup mode for
balancing
balancing
a thermal line extender (no
AGC)
AGC)
line extender only
compensation mode for
balancing
compensation mode for
balancing
a thermal line extender (no
AGC)
AGC)
line extender and coax
compensation mode for
balancing
compensation mode for
balancing
Forward Path Balancing for
Thermal Stations Using Line
Extender and Coax
Compensation Mode (on page
69)
Thermal Stations Using Line
Extender and Coax
Compensation Mode (on page
69)
a manual line extender (no
AGC)
AGC)
N/A
Forward Path Balancing for
Manual Stations (on page 73)
Manual Stations (on page 73)
an line extender configured
with AGC
with AGC
a trim network for balancing
Forward Path Balancing for AGC Stations Using Manual Setup Mode
Before you begin, make sure that you have configured the line extender module
according to the specifications in the design print, and that the line extender has
warmed up for approximately one hour.
according to the specifications in the design print, and that the line extender has
warmed up for approximately one hour.
To Set the Manual Backoff Level
You must adjust the manual backoff level.