Cisco Cisco 1 GHz GainMaker Amplifier インストールガイド

ページ / 132
 
Chapter 3        Balancing and Setup 
 
 
 
48 
 
Bode Mode 
Description 
Note 
Manual mode 
Bode circuit is by-passed, the 
bode functions are disabled. 
You can only use the forward 
path balancing procedure in 
Forward Path Balancing for 
Manual Stations
 (on page 73) 
To Select the Forward Path Balancing Procedure 
Refer to the following table to direct you to the proper starting point to balance your 
line extender using your preferred method. 
If you have ... 
and you use ... 
go to ... 
a line extender configured 
with AGC 
manual mode for balancing 
Forward Path Balancing for 
AGC Stations Using Manual 
Setup Mode
 (on page 48) 
a line extender configured 
with AGC 
thermal setup mode for 
balancing 
Forward Path Balancing for 
AGC Stations Using Thermal 
Setup Mode
 (on page 58) 
a thermal line extender (no 
AGC) 
line extender only 
compensation mode for 
balancing 
Forward Path Balancing for 
Thermal Stations Using Line 
Extender Only Compensation 
Mode
 (on page 66) 
a thermal line extender (no 
AGC) 
line extender and coax 
compensation mode for 
balancing 
Forward Path Balancing for 
Thermal Stations Using Line 
Extender and Coax 
Compensation Mode
 (on page 
69) 
a manual line extender (no 
AGC) 
N/A 
Forward Path Balancing for 
Manual Stations
 (on page 73) 
an line extender configured 
with AGC 
a trim network for balancing 
Forward Path Balancing 
Using Trim Networks
 (on page 
75) 
 
Forward Path Balancing for AGC Stations Using Manual Setup Mode 
Before you begin, make sure that you have configured the line extender module 
according to the specifications in the design print, and that the line extender has 
warmed up for approximately one hour. 
 
To Set the Manual Backoff Level 
You must adjust the manual backoff level.