Samsung SMO-210TRP ユーザーズマニュアル

ページ / 174
3)  Loss occurrence information is stored in the ”EVENT LIST”.  
4)  When the corresponding camera is reconnected, the  old settings
are canceled and the factory default settings  are reinstated. 
4. Door Bell Occurrence
The Door Bell option is only available when a Door Bell Box is con-
nected.
1)  When a door bell is pressed, the current picture switches to the
doorbell area monitoring picture, in full screen mode, along with
an alarming beep. 
2)  When the Door Bell is pressed, a still screen is stored in the
“DOOR BELL LIST”. 
3)  Up to 8 still images can be stored in the “DOOR BELL LIST” and
the selected List can be displayed  on the screen.
4)  Select the desired list from “6. DOOR BELL LIST ” in the
SETUP MENU and press ENTER in to replay the still screen of
the corresponding Door Bell. 
Press ENTER again to return to the “DOOR BELL LIST”. 
Appendix
Specifications
1. Model Name
- SMO-210TRN(P)
- SMO-150TRN(P)
2. Video Input
- CAMERA 8 Input : 1.0Vp-p, 75Ω (vertical), 
RJ-45 Type, CVBS
- VCR 1 Input (to Video Out of VCR) : 1.0Vp-p, 75Ω (vertical),  
S-Jack Type, CVBS
3. Video Output
- Monitor 2 Output
SPOT : 1.0 Vp-p, 75Ω (vertical), S-Jack Type, CVBS
SLAVE : 1.0 Vp-p, 75Ω (vertical), S-Jack Type, CVBS
- VCR 1 Output : 1.0 Vp-p, 75Ω (vertical), S-Jack Type, CVBS
4. Voice Input
- CAMERA 8 Input: RJ-45 Type
- VCR 1 Input (Audio Out-VCR) : S-Jack Type
5. Voice Output
- SPOT Audio
- VCR Audio
6. Alarm/Motion Function: Connected Alarm Box/Camera
- A/O (HOT, COLD): Relay Active
- A/R (Alarm Reset): Open Collector “L ” Level, 
Pulse Width = 150ms or above
-Alarm Hold Time: Select 5sec, 15sec, 30sec, 1min, 3min, 5min,
10min, 20min, 30min, or AUTO.
- If AUTO is selected, the Alarm will be on during the time the Alarm 
trigger is received.
7. Sequence:
Select between 01 sec to 30 sec.
8. Event Replay
- Alarm/Motion/Loss: Max. 16 Frames per Channel
- Door Bell: Max. 8 Frames
9. List
- Alarm/Loss/Motion: Saving Max. 50
- Door Bell: Max. 8
10. Multi Screen
- Full, 4, 8, 9, 16, Zoom, PIP
11. Horizontal Resolution  
- 400 TV Lines or more (Live Mode Full Screen)
12. Memory Back Up
- 5 Years or more
13. Operation Temperature
- 0 °C ~ 40 °C
14. Built-in Clock 
- ± 1 Minute/Month or less
15. CRT
- SMO-210TRN(P) : 21”FLAT CRT
- SMO-150TRN(P) : 15”FLAT CRT
16. Dimensions (W x H x D)
- SMO-210TRN(P) : 520 x 509 x 486
- SMO-150TRN(P) : 388 x 459 x 379
17. Weight
- SMO-210TRN(P) :  28kg (without packing)
32.5kg (with packing)
- SMO-150TRN(P) :  15.2kg (without packing)
18.5kg (with packing)
18. Power consumption 
- Please see the regulatory label attached  on the back of the monitor.
19. Video system 
- SMO-210TRP/150TRP: ONLY PAL VIDEO SYSTEM
- SMO-210TRN/150TRN: ONLY NTSC VIDEO SYSTEM