Samsung SNC-C6225P ユーザーズマニュアル

ページ / 76
30 – 10x Network Mini Smart Dome Camera
how to use osd menu
PRESET SETUP
PRESET NO. 
[1~128]
If a selected preset is already defi ned, camera moves 
to pre-defi ned position and preset characteristics 
such as Label and Relay Outputs show on monitor. 
If a selected preset is not defi ned, “UNDEFINED” 
shows on monitor.
EDIT PRESET SCENE
Redefi ne current Preset scene position (i.e. PTZ). 
EDIT PRESET LABEL
Edits Label to show on monitor when preset runs. 
Max. 10 alphabets are allowed.
CLR PRESET 
[CANCEL/OK]
Delete current Preset data
CAM ADJUST 
[GENERAL/SPECIAL]
WB(White Balance) and AE(Auto Exposure) can be set 
up independently for each preset. There are 2 modes, 
GENERAL” mode & “SPECIAL” mode. The General 
mode means that WB or AE can be set up totally and 
simultaneously for all presets in “CAMERA SETUP” 
menu. 
The Special mode means that WB or AE can be set 
up independently or separately for each preset in each 
preset setup menu. Each Special WB/AE value should 
activate correspondingly when camera arrives at each 
preset location. During jog operation, General WB/AE 
value should be applied.
All Special WB/AE value should not change although 
General WB/AE value changes. If “SPECIAL” is 
selected, Menu to set WB/AE shows on monitor.
ALARM OUT
Relay Output can be linked with Preset run. 
The character “-” means disable while the number “1” 
representing each bit means ON. 
ex) If it is set to “1”, Output relay will be ON whenever 
you call this Preset.
Edit Preset Scene
c  Using joystick, move camera to desired position.
d By pressing ENTER key, save current PTZ data.
Edit Preset Label
c  Edits label to show on monitor when camera 
arrives at presets. In Edit Label menu, a reverse 
rectangular is cursor. As soon as fi nishing selecting 
alphabet, cursor moves to the next digit. 
d Using Left/Right/Up/Down of joystick, move to 
an appropriate character from the Character set. 
To choose that character, press the ENTER key.
PRESET SETUP 
PRESET NO. 
1
<EDIT SCENE>
<LABEL> 
CLR PRESET 
CANCEL
CAM ADJUST 
GENERAL
ALARM OUT 
----
BACK
EXIT
EDIT SCENE - PRESET 1
MOVE TO TARGET POSITION
[ENTER : SELECT]
0/0/x1/N
LABEL - PRESET 1
[█         ]
 ----------
 1234567890 
OK
 ABCDEFGHIJ 
CANCEL
 KLMNOPQRST
 UVWXYZabcd
 efghijklmn
 opqrstuvwx
 yz<>-/:.
Current Cursor Position
  [          ]