HP proliant dl580 ユーザーズマニュアル
Diagnostic tools 65
1.
Bring the server to base configuration by removing all components that are not required by the
server to complete POST. This process can include removing all:
server to complete POST. This process can include removing all:
•
•
Processors ("
), except the processor installed in socket 1
IMPORTANT: Processor socket 1 and PPM slot 1 must be populated at all times or the server does not
function properly.
•
), except the PPM installed in slot 1
•
DIMMs ("
•
•
Peripheral devices
2.
Reseat the processor in socket 1.
3.
Reseat the remaining processors, rebooting after each installation to identify any failed processors.
IMPORTANT: Populate the processors in the following order: 1, 2, 4, 3.
IMPORTANT: Always install a PPM when you install a processor. The system fails to boot if the PPM is
missing.
4.
Replace the processor in socket 1.
5.
Replace the processor board, if applicable.
6.
Replace the system board.
IMPORTANT: If replacing the system board or clearing NVRAM, you must re-enter the server serial number
through RBSU ("
Expansion board-related port 85 codes
Expansion board-related port 85 codes display in the format 6xh.
IMPORTANT: Reboot the server after completing each numbered step. If the error condition continues,
proceed with the next step.
To troubleshoot expansion board-related error codes:
1.
Reseat all expansion boards.
2.
Bring the server to base configuration by removing all components that are not required by the
server to complete POST. This process can include removing all:
server to complete POST. This process can include removing all:
•
•
Processors ("
), except the processor installed in socket 1
IMPORTANT: Processor socket 1 and PPM slot 1 must be populated at all times or the server does not
function properly.
•
), except the PPM installed in slot 1
•
DIMMs ("
•
•
Peripheral devices