HP ProLiant ML330 G6 ユーザーズマニュアル

ページ / 129
 
Operations 22 
Open or remove the tower bezel, as needed ("
). 
Extend the server from the rack (on page 
3. 
Loosen the access panel screws. 
4. 
Slide the access panel back about 1.5 cm (0.5 in). 
5. 
Lift and remove the access panel. 
  
 
CAUTION: 
 For proper cooling, do not operate the server without the access panel, baffles, 
expansion slot covers, hard drives, or blanks installed. 
  
 
Install the access panel 
1. 
Place the access panel on top of the server, allowing it to extend past the rear of the server 
approximately 1.5 cm (0.5 in). 
2. 
Slide the access panel forward until it clicks into place, and close the access panel latch.  
 
Remove the air baffle 
1. 
Power down the server (on page 
2. 
Do one of the following: 
Open or remove the tower bezel, as needed ("
). 
Extend the server from the rack (on page 
3. 
Remove the access panel (on page 
). 
4. 
Remove the air baffle. 
 
If necessary, configure the air baffle (on page 
 
Configure the air baffle 
This procedure is necessary for 2P models only.