Canon galvano gc-251 ユーザーズマニュアル

ページ / 88
 
CANON    Digital Galvano Scanner System
 
KP-1SM Series + GC-251 
Users Manual 1.00 
 
 
 
  
22
(Target Position Data)  XDATYDAT 
The data length of the target position data by the high-speed serial communication can be 
changed by two following parameters. 
 
The target position data length can be changed in 16bit – 20bit. 
Parameter ID 
DATA 
67
 
16:  16bit  Data  ※ 
17:  17bit  Data 
18:  18bit  Data 
19:  19bit  Data 
20:  20bit  Data 
 
The least significant bit position of the target position data of high-speed serial communication 
20bit data can be set by following parameter. 
The right shifts this number of bit make the target position data. 
 
Parameter ID 
DATA 
68
 
0:  0bit  position 
1:  1bit  position  ※ 
2:  2bit  position 
3:  3bit  position 
4:  4bit  position 
 
 
    An example of the setting as follows. 
 
 
       
Parameter ID = 67    16 
                Parameter ID = 68        1 
 
 
 
       
Parameter ID = 67    18 
                Parameter ID = 68        2 
 
 
(Bit)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
XDAT
C2
C1
C0
D15 D14 D13 D12 D11 D10 D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
P
YDAT
C2
C1
C0
D15 D14 D13 D12 D11 D10 D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
P
16bit
Data
(Bit)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
XDAT
D17 D16 D15 D14 D13 D12 D11 D10 D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
C1
C0
YDAT
D17 D16 D15 D14 D13 D12 D11 D10 D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
C1
C0
18bit
Data