Parameter ID = 67    20 
                Parameter ID = 68        0 
 
 
With the default settings at shipping, the setting is ※ (16bit position data length, data least 
significant bit 1bit position). 
This communication specification has compatibility of XY2-100.     
When using the scanner controller of XY2-100 specifications, please use this setting. 
 
Motor rotating angle for the high-speed serial communication data 
・  In the case of 16bit position data 
Data: 1 for one pulse that can be specified up to the following positions: 
Maximum position:   
0xFFFF = 32767 pulses = About 5.76 deg (GM-1010) 
0-pulse position:   
0x8000 = 0 
Minimum position:   
0x0000 = –32768 pulses = About –5.76 deg (GM-1010) 
 
If a greater angle is specified, set a magnification by using the High-speed Serial Communication 
Conversion Gain parameter (Parameter ID = 13) 
 
E.g.    For x2 (Setting: 2000), the following angle can be specified: 
         
 
     
–5.76 × 2 deg    to    5.76 × 2 deg 
       
The command resolution will be two times. 
 
・  In the case of 20bit position data
 
Data: 1 for one pulse that can be specified up to the following positions: 
Maximum position:   
0xFFFF = 524287 pulses   
0-pulse position:   
0x8000 = 0 
Minimum position:   
0x0000 = –524287 pulses 
 
Maximum movable range is set with Parameter ID = 0, 1 (CW limit, CCW limit). 
The position data of high-speed serial communication can not exceeded this range. 
(Bit)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
XDAT
D19 D18 D17 D16 D15 D14 D13 D12 D11 D10 D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
YDAT
D19 D18 D17 D16 D15 D14 D13 D12 D11 D10 D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
20bit
Data