Install the Router without Using a Mechanical Lift
M40 Internet Router Hardware Guide
114
Reinstall the FPCs
The FPCs install into the card cage at the front of the chassis, as shown in Figure 1. 
To reinstall the FPCs, follow this procedure:
1.
Attach an ESD strap to your bare wrist and connect the strap to one of the ESD points on 
the chassis.
2.
Locate the leftmost slot in the FPC card cage on the front of the chassis. It is directly 
above the offline button on the craft interface that is labeled 
0
 (zero).
3.
Locate the FPC that you labeled 
0
 during removal. Verify that the ends of the extractor 
clips, which are located at each end of the FPC, are pushed outward, toward the ends of 
the FPC.
4.
Grasp the front of the FPC with both hands and align the rear of the card carrier with the 
slide guides in the card cage.
5.
Slide the FPC all the way into the card cage until it contacts the backplane.
6.
Push the ends of the extractor clips toward each other to secure the FPC in the chassis.
7.
Using a Phillips screwdriver, tighten the thumbscrew at each end of the FPC to seat the 
unit firmly in the chassis.
8.
Repeat Steps 4 through 7 for each FPC, proceeding from left to right through the 
remaining FPC slots. 
To help you work systematically, the following procedure 
directs you to reinstall FPCs starting at the left side of the 
card cage and working toward the right. You can install 
FPCs in any order, however. 
Be sure there is a blank panel over every empty slot. The 
blank panels must be in place during router operation to 
guarantee adequate circulation of cooling air.