Troubleshooting 
Problems After Initial Boot 
Once the server has passed POST, you may still encounter errors, such as an inability to load 
the operating system. Use the Table 5-7 to troubleshoot server installation problems that 
occur after the initial boot. 
Refer to the HP Servers Troubleshooting Guide for more information. 
 
Table 5-7:  Problems After Initial Boot 
Problem Possible 
Reasons Possible 
Solutions 
SmartStart requirement not 
performed. 
Check the SmartStart Release Notes 
provided in the SmartStart Online 
Reference Information on the 
SmartStart CD. 
IDE cable or power cable 
not connected to 
CD-ROM drive. 
Check the IDE signal cable between 
the system board and CD-ROM to 
ensure proper connection. 
Check the power supply connection 
between the CD-ROM drive and the 
power backplane. 
Insufficient memory is 
available. 
A rare “insufficient memory” message 
may display the 
first
 time SmartStart 
is booted on certain unconfigured 
systems. Cold-boot the machine with 
the SmartStart CD inserted in the CD-
ROM drive to correct the problem. 
System cannot load 
SmartStart. 
 
Existing software is causing 
conflict. 
Run the HP System Erase Utility. 
Read the
 
Caution at the end of this 
table. Refer to the instructions in the 
HP Servers Troubleshooting Guide