Vertex Standard FT-2000 ユーザーズマニュアル

ページ / 132
Page 114
FT-2000 O
PERATING
 M
ANUAL
022 tEy CW MEM3
Function: Permits entry of the CW message for message
register 3.
Available Values: tyP1/tyP2
Default Setting: tyP2
tyP1: You may enter the CW message from the front
panel’s Function Keys.
tyP2: You may enter the CW message from the CW
keyer.
023 tEy CW MEM4
Function: Permits entry of the CW message for message
register 4.
Available Values: tyP1/tyP2
Default Setting: tyP2
tyP1: You may enter the CW message from the front
panel’s Function Keys.
tyP2: You may enter the CW message from the CW
keyer.
024 tEy CW MEM5
Function: Permits entry of the CW message for message
register 5.
Available Values: tyP1/tyP2
Default Setting: tyP2
tyP1: You may enter the CW message from the front
panel’s Function Keys.
tyP2: You may enter the CW message from the CW
keyer.
A
DVICE
:
If the optional FH-2 Remote Control Keypad is not con-
nected, this adjustment has no effect.
GENERAL G
ROUP
025 GEnE ANT SEL
Function: Sets the method of antenna selection.
Available Values: bAnd/rEG
Default Setting: bAnd
bAnd:The antenna is selected in accordance with the
operating band.
rEG: The antenna is selected in accordance with the
band stack (different antennas may be utilized
on the same band, if so selected in the band
stack).
026 GEnE BEP LVL
Function: Sets the beep level.
Available Values: 0 ~ 255
Default Setting: 50
027 GEnE CAT BPS
Function: Sets the transceiver’s computer-interface cir-
cuitry for the CAT baud rate to be used.
Available Values: 4800/9600/192H(19200)/384H (38400)
bps
Default Setting: 4800 bps
028 GEnE CAT TOT
Function: Sets the Time-Out Timer countdown time for a
CAT command input.
Available Values: 10/100/1000/3000 msec
Default Setting: 10 msec
The Time-Out Timer shuts off the CAT data input after the
continuous transmission of the programmed time.
029 GEnE CAT RTS
Function: Enables/Disables the RTS port of the CAT jack.
Available Values: On/OFF
Default Setting: On
030 GEnE MEM GRP
Function: Enables/Disables Memory Group Operation.
Available Values: On/OFF
Default Setting: OFF
031 GEnE Q SPLIT
Function: Selects the tuning offset for the Quick Split fea-
ture.
Available Values: –20 ~ 0 ~ +20 kHz (1 kHz Step)
Default Setting: +5 kHz
M
ENU
 M
ODE
KEYER G
ROUP