FT-2000 O
PERATING
 M
ANUAL
032 GEnE TRACK
Function: Sets the VFO Tracking feature.
Available Values: OFF/bAND/FrEq
Default Setting: OFF
OFF:
Disables the VFO Tracking feature.
bAND: When you change bands on the Main (VFO-
A) side, the Sub (VFO-B) band’s VFO will
automatically change to be the same as that of
VFO-A.
FrEq:
This function is the almost same as “bAND,”
however, furthermore, the Sub band’s (VFO-
B) frequency changes together with the Main
Band’s (VFO-A) frequency when turning the
Main Dial Tuning knob.
033 GEnE TX TOT
Function: Sets the Time-Out Timer countdown time.
Available Values: OFF/5/10/15/20/25/30 min
Default Setting: OFF
The Time-Out Timer shuts off the transmitter after con-
tinuous transmission of the programmed time.
034 GEnE TRV SET
Function: Sets the 10’s and 1’s of the MHz digits display
for operation with a transverter.
Available Values: 30 ~ 49 MHz
Default Setting: 44 MHz
The default setting would be used with a 144 MHz
transverter. If you connect a 430 MHz transverter to the
radio, set this menu to “30” (the “100 MHz” digits are
hidden on this radio).
035 GEnE µT DIAL
Function: Selects the µ-TUNE mode.
Available Values: StP1/ StP2/OFF
Default Setting: StP1
StP-1: A c t i v a t e s  t h e  µ - T U N E   s y s t e m   u s i n g
“COARSE” steps of the [VRF] knob (2 steps/
click) on the 7 MHz and lower amateur bands.
On the 10/14 MHz bands, “FINE” [VRF] knob
steps (1 step/click) will be used.
StP2: Activates the µ-TUNE system using “FINE”
steps of the [VRF] knob (1 step/click) on the
14 MHz and lower amateur bands on the Main
band (VFO-A).
OFF: Disables the µ-TUNE system. Activates the
VRF feature on the 14 MHz and lower amateur
bands on the main band (VFO-A).
A
DVICE
:
If the optional RF µTuning Kit is not connected, this ad-
justment has no effect.
036 GEnE SNB LVL
Function: Adjusts the Sub band (VFO-B) receiver’s IF
Noise Blanker level, when the Noise Blanker is engaged.
Available Values: nAin(MAIN)/0~100
Default Setting: nAin(MAIN)
When this menu is set to “nAin(MAIN),” you may adjust
the Noise Blanker level using the front panel’s [NB] knob.
037 GEnE SUB FIL
Function: Defines the Sub band (VFO-B) receiver’s CW
narrow filter.
Available Values: 1200/300/500 Hz
Default Setting: 1200 Hz
A
DVICE
:
This Menu item tells the microprocessor which (if any)
optional filter has been installed.
038 GEnE MIC SCN
Function: Enables/disables scanning access via the
microphone’s [UP]/[DWN] keys.
Available Values: On/OFF
Default Setting: On
039 GEnE SCN RSM
Function: Selects the Scan Resume mode.
Available Values: CAr/5SEc
Default Setting: 5SEc
CAr: The scanner will hold until the signal disappears,
then will resume after one second.
5SEc: The scanner will hold for five seconds, then re-
sume whether or not the other station is still
transmitting.
040 GEnE ANTIVOX
Function: Adjusts the Anti-VOX Trip Gain which is the
level of negative feedback of receiver audio to the micro-
phone, to prevent receiver audio from activating the trans-
mitter (via the microphone) during VOX operation.
Available Values: 0 ~ 100
Default Setting: 50
041 GEnE FRQ ADJ
Function: Adjusts the reference oscillator.
Available Values: –25 ~ 0 ~ +25
Default Setting: 0
Connect a 50-Ohm dummy load and frequency counter to
the antenna jack; adjust the [SUB VFO-B] knob so that
the frequency counter reading is same as the VFO fre-
quency while pressing the PTT switch.
A
DVICE
:
Do not perform this Menu item unless you have a high-
performance frequency counter. Perform this Menu item
after aging the transceiver and frequency counter suffi-
ciently (at least 30 minutes).
M
ENU
 M
ODE
GENERAL G