The RRG Series Griddles utilize a solenoid valve with 
a brass pilot valve to control gas flow to pilot burners. 
One to three pilot flames can be fed by one valve – 
one leg of which may be branched. 
 
PILOT TROUBLESHOOTING 
 
SYMPTOM – PILOT WILL NOT LIGHT 
1.  Check pilot adjustment at solenoid valve 
2.  Check that power switch is on 
3.  Check that pilot solenoid valve is working 
4.  Check that safety ignition module and power switch are working 
5.  Check gas pressure 
6.  Check for air in the line 
 
PILOT ASSEMBLY REMOVAL 
 
 Disconnect the electrical power and follow lockout / tagout procedures
 
 Shut off gas supply 
 
 
1.  Remove control panel. Reaching  
      underneath the front of the unit, 
      remove the pilot tube fitting and 
      disengage the pilot tube from the pilot. 
2.  Reaching underneath the front of the 
      unit, remove the pilot bracket retaining 
      screw(#2 Phillips) and remove the  
      entire assembly out through the pilot 
      access cutout and  out from under the 
      unit. 
3.  Disconnect the electrode wire from the 
from the safety ignition module. 
4.  Remove the pilot from the bracket. 
5.  Reverse procedure to install 
6.  Verify gas pressure and check for 
proper operation 
 
 All gas joints disturbed during servicing must be checked for leaks. 
Check with a soap and water solution.  Do not use an open flame.
 
BRASS PILOT 
VALVE
          BRACKET RETAINING SCREW 
PILOT ASSEMBLY 
ELECTRODE 
      PILOT  
    ACCESS 
CUTOUT