FMI pfs us gwrp16c ユーザーズマニュアル

ページ / 28
www.fmiproducts.com
125311-01A
16
OPERATION 
Continued
THERMOSTAT CONTROL 
OPERATION
The  thermostatic  control  used  on  these 
models  differs  from  standard  thermostats. 
Standard thermostats simply turn on and off 
the burner. The thermostat used on this heater 
senses the room temperature. At times the 
room may exceed the set temperature. If so, 
the burner will shut off. The burner will cycle 
back on when room temperature drops below 
the set temperature. The control knob can be 
set to any comfort level between 1 and 5. All 
plaques will turn off and on.
Note:  The  thermostat  sensing  bulb  mea-
sures the temperature of air near the heater 
cabinet.  This  may  not  always  agree  with 
room  temperature  (depending  on  housing 
construction, installation location, room size, 
open air temperatures, etc.) Frequent use of 
your heater will let you determine your own 
comfort levels.
MANUAL LIGHTING 
PROCEDURE
1.  Remove front panel (see Figure 7, page 9). 
2.  Follow steps 1 through 5 under Lighting 
Instructions, page 14.
3.  With control knob pressed in, strike match. 
Hold match to pilot until pilot lights.
4.  Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds, 
release control knob. Now follow step 9 
under Lighting Instructions, page 14.
5.  Replace front panel. 
BLOWER 
OPERATION
  WARNING:  Blower  acces-
sory must be grounded. Blower 
comes  with  a  three-prong, 
grounding  plug  as  shown  in 
Figure  24.  The  plug  is  your 
protection  against  electrical 
shock. Plug it into a standard, 
three-hole, grounded, outlet. If 
cord needs replacing, use only a 
cord with a three-prong, ground-
ing plug.
  CAUTION:  Label  all  wires 
prior  to  disconnection  when 
servicing controls. Wiring errors 
can cause improper and danger-
ous operation. 
 CAUTION: Do not plug power 
cord into electrical outlet until 
installation is complete.
Extension Cord
Use extension cord if needed. The cord must 
have  a  three-prong,  grounding  plug  and  a 
three-hole receptacle. Make sure cord is in 
good shape. It must be heavy enough to carry 
the current needed. An undersized cord will 
cause a drop in line voltage. This will result in 
loss of power and overheating. Use a No. 16 
AWG cord for lengths less than 50 feet. 
 CAUTION: Verify proper op-
eration after servicing.
Operating Blower
The  blower  is  connected  to  a  thermostat. 
When unit heats up, the blower will operate. 
A few minutes after unit cycles off or is turned 
off, blower will shut off. Blower will cycle on 
and off in this manner. Note: If you have a 
heater  with  a  thermostat,  the  heater  and 
blower will not turn off and on at exactly the 
same time. Blower cycle times will vary with 
heat setting selected.
Grounded 
Outlet
Figure 24 - Grounding Plug
Thermostat
Sensor
Switch
Green
White
Green
White
110/115 
V.A.C.
Blower
Motor
Black 
Black 
Figure 25 - Wiring Diagram for Blower 
Accessory