FMI pfs us gwrp16c ユーザーズマニュアル

ページ / 28
www.fmiproducts.com
125311-01A
17
 WARNING: Failure to keep 
the  primary  air  opening(s)  of 
the burner(s) clean may result in 
sooting and property damage.
ODS/PILOT AND BURNER
Use  a  vacuum  cleaner,  pressurized  air  or 
small, soft bristled brush to clean.
BURNER PILOT AIR INLET
The primary air inlet holes allow the proper amount 
of air to mix with the gas. This provides a clean 
burning flame. Keep these holes clear of dust, dirt 
and lint. Clean these air inlet holes prior to each 
heating season. Blocked air holes will create soot. 
We recommend that you clean the unit every 
three months during operation and have heater 
inspected yearly by a qualified service person.
Thermocouple
Pilot Burner
Pilot Burner
Thermocouple
Blue Flame
Yellow Flame
INSPECTING HEATERS
Figure 26 - Correct Pilot Flame Pattern
Figure 27 - Incorrect Pilot Flame Pattern
BURNER FLAME PATTERN
Figure 28 shows a correct burner flame pat-
tern.  Figure  29  shows  an  incorrect  burner 
flame pattern. 
If burner flame pattern is incorrect, as shown 
in Figure 29
• turn heater off (see To Turn Off Gas to Ap-
pliance, page 15)
• see Troubleshooting, page 18
CLEANING AND MAINTENANCE
Check pilot flame pattern and burner flame 
patterns often.
PILOT FLAME PATTERN
Figure 26 shows a correct pilot flame pattern. 
Figure 27 shows an incorrect pilot flame pat-
tern. The incorrect pilot flame is not touching the 
thermocouple. This will cause the thermocouple 
to  cool.  When  the  thermocouple  cools,  the 
heater will shut down.
If pilot flame pattern is incorrect, as shown 
in Figure 27
•  turn heater off (see To Turn Off Gas to Ap-
pliance, page 15)
•  see Troubleshooting, page 18
Note: The pilot flame on natural gas units will 
have a slight curve, but flame should be blue 
and have no yellow or orange color. 
  WARNING:  Turn  off  heater 
and let cool before cleaning.
  CAUTION:  You  must  keep 
control areas, burner and circu-
lating air passageways of heater 
clean.  Inspect  these  areas  of 
heater  before  each  use.  Have 
heater  inspected  yearly  by  a 
qualified service person. Heater 
may need more frequent clean-
ing  due  to  excessive  lint  from 
carpeting, bedding material, pet 
hair, etc.
Figure 28 - Correct Burner Flame Pattern
Figure 29 - Incorrect Burner Flame 
Pattern