We also recommend that you keep the burner 
tube and pilot assembly clean and free of dust 
and dirt. To clean these parts we recommend 
using compressed air no greater than 30 PSI. 
Your local computer store, hardware store or 
home center may carry compressed air in a 
can. If using compressed air in a can, please 
follow the directions on the can. If you don’t 
follow directions on the can, you could dam-
age the pilot assembly.
1.  Shut off unit, including pilot. Allow unit to 
cool for at least thirty minutes.
2.  Inspect burner, pilot and primary air inlet 
holes on orifice holder for dust and dirt 
(see Figure 30).
3.  Blow air through the ports/slots and holes 
in the burner.
4.  Never inset objects into the pilot tube.
5.  Blow air into the primary air holes on the 
orifice holder.
Clean pilot assembly also. A yellow tip on the 
pilot flame indicates dust and dirt in the pilot 
Figure 30 - Pilot Inlet Air Hole
CLEANING AND MAINTENANCE
Continued
Pilot 
Assembly
Pilot Air 
Inlet Hole
CABINET
Air Passageways
Use pressurized air to clean.
Exterior
Use a soft cloth dampened with a mild soap 
and  water  mixture.  Wipe  the  cabinet  to  re-
move dust.
SPECIFICATIONS
GWRN18TC, VSHRN18T
•   Natural Gas Only
•   18,000 Btu/h
•   Pressure Regulator Setting: 6" W.C.
•   Inlet Gas Pressure* (in. of water):
  Maximum - 10.5" W.C., Minimum - 7" W.C.
GWRN30TC, VSHRN30T
•   Natural Gas Only
•   30,000 Btu/h
•   Pressure Regulator Setting: 6" W.C.
•   Inlet Gas Pressure* (in. of water):
  Maximum - 10.5" W.C., Minimum - 7" W.C.
GWRN18C, VSHRN18M
•   Natural Gas Only
•   6,600/12,000/18,000 Btu/h
•   Pressure Regulator Setting: 6" W.C.
•   Inlet Gas Pressure* (in. of water):
  Maximum - 10.5" W.C., Minimum - 7" W.C.
GWRN30C, VSHRN30M
•   Natural Gas Only
•   6,600/18,000/30,000 Btu/h
•   Pressure Regulator Setting: 6" W.C.
•   Inlet Gas Pressure* (in. of water):
  Maximum - 10.5" W.C., Minimum - 7" W.C
GWRP16TC, VSHRP16T
•   Propane/LP Gas Only
•   16,000 Btu/h
•   Pressure Regulator Setting: 8" W.C.
•   Inlet Gas Pressure* (in. of water):
  Maximum - 14" W.C., Minimum - 11" W.C.
GWRP26TC, VSHRP26T
•   Propane/LP Gas Only
•   26,000 Btu/h
•   Pressure Regulator Setting: 8" W.C.
•   Inlet Gas Pressure* (in. of water):
  Maximum - 14" W.C., Minimum - 11" W.C.
GWRP16C, VSHRP16M
•   Propane/LP Gas Only
•   6,000/11,000/16,000/ Btu/h
•   Pressure Regulator Setting: 8" W.C.
•   Inlet Gas Pressure* (in. of water):
  Maximum - 14" W.C., Minimum - 11" W.C.
GWRP26C, VSHRP26M
•   Propane/LP Gas Only
•   6,000/16,000/26,000 Btu/h
•   Pressure Regulator Setting: 8" W.C.
•   Inlet Gas Pressure* (in. of water):
  Maximum - 14" W.C., Minimum - 11" W.C.
* For purposes of input adjustment.
assembly. There is a small pilot air inlet hole 
about 2" from where the pilot flame comes out 
of the pilot assembly (see Figure 30). With the 
unit off, lightly blow air through the air inlet 
hole. You may blow through a drinking straw 
if compressed air is not available.