The aircraft will automatically descend and land if Failsafe RTH is triggered when the aircraft
is within a 20 meter (65 feet) radius of the Home Point. During the RTH procedure, if you move
the throttle stick after the aircraft rises above 65 feet (20m), the aircraft will stop ascending and
immediately return to the Home Point.
The aircraft cannot Return-to-Home if the signal is weak ( [
] is grey).
The aircraft cannot avoid obstacles during the Failsafe RTH procedure, and therefore it is
important to set a suitable Return-to-Home altitude before each flight. Go to the DJI GO app >
Camera View > > Advanced Settings > Failsafe Mode to set the Failsafe altitude.
Camera View > > Advanced Settings > Failsafe Mode to set the Failsafe altitude.
Failsafe RTH
Failsafe RTH will be triggered if the remote controller signal is lost for more than three seconds, provided
that a Home Point was recorded previously. You can regain control of the aircraft if the remote controller
signal is recovered.
① Record the Home Point
Aircraft Status Indicator:
Flashing Yellow Flashing Green
② Flying
Aircraft Status Indicator:
Flashing Green
③ Remote Controller Signal Lost
Aircraft Status Indicator:
Flashing Yellow
×
④ Signal Lost > 3s, Return-to-Home
Aircraft Status Indicator:
Flashing Yellow
>3s
×
⑥ Auto Landing after Hovering for 15s
Aircraft Status Indicator:
Flashing Yellow
×
Failsafe RTH Illustration
⑤ Return to the Home Point
Aircraft Status Indicator:
Flashing Yellow
Height over Home Point >20m
Ascend to 20m
Height over Home Point <=20m
20m
×
20米
20米
H
The aircraft cannot avoid obstruction during the Failsafe RTH, therefore, it
is important to set an suitable Failsafe altitude before each flight. Launch
the DJI GO app and enter “Camera” and select “MODE > Advanced
Settings > Failsafe mode” to set the Failsafe altitude.
20 m
20 m
H
If the aircraft is flying under 20 meters (65 feet) and Failsafe (including
Smart RTH, Lower Battery RTH ) is triggered, the aircraft will first
automatically ascend to 20 meters (65 feet) from the current altitude. You
Failsafe and regain the control of the remote controller.
20 m
20 m
H
Aircraft automatically descends and lands if RTH is triggered when the
aircraft flies within a 20 meters (65 feet) radius of the Home Point. Aircraft
will stop ascending and immediately return to the Home Point if you move
the throttle stick if the aircraft reaches 20 meters (65 feet) altitudes or
beyond during Failsafe.