RACAM - TECH LTD 1014401 ユーザーズマニュアル

ページ / 34
Operating the System 
24 
4. 
To stop an event press Hold. The TU will send a disarm command to the 
RCUs. Any RCU that hasn't received yet a firing command will return to 
Standby state with the red light blinking. The command key LEDs will get into 
the following condition:  
 
Key LED 
Color 
Send Red 
Ready Green 
Hold Red 
Group Green 
 
 
Firing In Semi-Automatic Mode 
1. 
The display will be as follows: 
 
 20:17:10        
EVENT:1  GROUP:1 
MODE:  S-AUTO    
                
 
 
2. 
Press the PTT and press the Send key. A firework will fire in the pre-
programmed order every time you press the Send key. The command key LED 
of any fired unit will turn from green to red. Any RCU that has functioned will 
shut down automatically. You can increment the group number by 1 by 
pressing the Group key. When current Group number is 16, pressing on the 
Group key will bring you to Group 1.  
3. 
To stop an event press Hold. The TU will send a disarm command to the 
RCUs. Any RCU that hasn't received yet a firing command will return to 
Standby state with the red light blinking. The command key LEDs will get into 
the following condition:  
 
Key LED 
Color 
Send Red 
Ready Green 
Hold Red 
Group Green 
Activation Keys 
 
 
Firing In Automatic Mode 
1. 
The display will be as follows: