When the temperature is over 405 deg F the display will show: 
OVL = Over Value Limit 
P I  T 
  O V L 
M E A T   O V L 
 
When the temperature is below 32 deg F the display will show: 
P I  T 
 L 
M E A T   L O W 
6.2.Aux Screen 
Shows the Aux 1 and 2 thermocouple temperatures 
A U X 1   1 0 5 
A U X 2   1 2 5 
6.3.Pit Setpoint Screen 
Using the up and down keys the user can adjust the pit setpoint from 32 to 400 deg F.  
The default setting is 275 deg F 
P I  T   S E T  
7 5      
6.4.Meat Setpoint Screen 
Using the up and down keys the user can adjust the meat setpoint from 32 to 210 deg F.  
The default setting is 185 deg F 
M E A T   S E T 
8 5      
6.5.Timer Screen 
Using the up and down keys the user can adjust the cook timer duration, also displays the 
actual current time left in the cook.  If the handheld unit is powered down, the setting will 
go to 00:00. NOTE. From 00:00 press down key to go to 99:59 
I M 
   
0 0 :  0 0      
6.6.Timeout Action Screen 
Selects the timeout action no action, alarm, or shut down.  The default setting is no 
action. 
T I  M E  O U T