Therm-Omega-Tech Inc. 94030 ユーザーズマニュアル

ページ / 11
6.STANDARD USER MENU 
The screens are shown in the order they appear as the scroll key is pressed.  When the 
battery power screen is reached and the scroll key is pressed again the menu system will 
loop around to the selected main screen. 
 
If the unit is left showing any screen for more than 10 seconds it will revert to the 
selected Main Screen. 
6.1.Main Screen Selection 
When the ProCom 4 is turned on the standard main screen appears.  Pressing the up or 
down key scrolls through a selection of three main screens. 
6.1.1.Standard Main Screen 
The * shows when the fan is running.  The numbers to the right are the actual Pit and 
Meat thermocouple temperatures.   
P I  T 
  2 7 3 
M E A T   1 8 0 
 
From the standard main screen, if the up key is hit the setpoint screen is shown. 
6.1.2.Setpoint Main Screen  
The actual values are to the left and the setpoints are to the right. 
P 2 7 3   2 7 5 
1 8 0   1 8 5 
 
If the up key is hit again Shot Gun Fred’s Screen is shown. 
6.1.3.Shot Gun Fred’s Main Screen 
This screen was designed for the advanced user and shows you the Pit Temp, Meat 
Temp, Cook Timer, Fan Status, and Fan %. 
“R” is shown when the control is actively ramping. 
“r” is shown when ramp is enabled but not active. 
% Fan shows 0-9 and F for fan running full time.   
P 2 7 3 M 1 8 0 
0 0 :  0 0 R * 5 
 
If the up key is hit again the standard main screen appears again. 
6.1.4.Temperature Display Messages 
When the controller is out of range or interference is present the display will show screen 
below and then flash “MEAT TEMP UNKNOWN !”: 
P I  T 
  - - -