Installation and operation guide - 3 
3  Quick Start Guide 
 
INSTALLATION 
 
 
Insert the batteries in your fall detectors and set the rigid angled tube in place(see §5.1) 
 
 
Install your fall detector at the appropriate location on your pool, making sure that he tube immersion 
depth is correct: 8.5 in (+/- 1 in). Cut the rigid tube down to the right length if necessary. (see §5.2) 
 
 
Switch your detector to ARMED mode (long beep – green indicator light flashing) by moving a magnet 
over the swimmer symbol. 
 
 
Carry out a fall test: from the top of the coping, drop a 2.5 US gallon jerry can filled so as to weigh 18 
lbs,  as  far  away  from  your  detector  as  possible.  The  siren  should  go  off  in  less  than  20  seconds.  (see 
§5.3) 
 
 
Turn the siren off by moving a magnet over the swimmer symbol. The red indicator light flashes. 
 
 
Fasten Swim Alert
TM
 on the edge of your pool using the attachment kit supplied.  
 
 
Wait for your device to restart automatically (long beep – green indicator light flashing). 
 
 
Your device is now operational (see §5.4) 
 
 
 
USE 
 
SIGNAL 
STATUS 
Green indicator light flashing
 
 
Detector in ARMED mode – Pool under surveillance 
Red indicator light flashing
 
 
Detector in DISARMED mode – Pool not monitored 
All indicator lights off 
 
Detector in OFF mode – Pool not monitored 
1 low-pitched beep every minute 
Batteries low: replace the 4 batteries in your fall detector 
2 low-pitched beeps every minute 
Malfunction requiring return to the after-sales service 
 
To switch between ARMED and DISARMED mode, move a magnet over the swimmer symbol.