S e r i e s   4 0 0 0   M a i n t e n a n c e   a n d   O p e r a t i o n s   M a n u a l
Wiring
Conduit & Fittings
The cable connecting the MTU to the 
instrument must be routed through the included 
conduit. Use the following procedure to install 
the conduit.
1)   
Remove the nut, sealing ring, and ferrule 
from one of the conduit fittings.
2)   
Slide the nut and sealing ring over the end 
of the conduit.
3)   
Insert the ferrule into the end of the conduit.
4)   
Thread the fitting body over the ferrule and 
secure by tightening the gland nut. Tighten 
the nut to 28-32 in-lb.
5)   
Repeat steps 1-4 to secure the remaining 
fitting to the other end of the conduit.
6)   
Remove a weather seal plug from the 
bottom of the MTU enclosure. 
7)   
Remove the lock ring from one of the 
conduit fittings and insert the fitting body 
into the opening in the bottom of the MTU.
8)   
Secure the fitting to the MTU with the lock 
ring. Tighten the ring to 15-19 in-lb.
9)   
Route the conduit to the instrument.
C
AUTION
 
Do not bend the conduit smaller than 
a 3" radius.
10) 
Remove the lock ring from the remaining 
conduit fitting and insert the fitting body 
into an available opening in the pressure 
monitor or volume corrector enclosure.
11) 
Secure the fitting to the instrument 
enclosure with the lock ring. Tighten the 
ring to 15-19 in-lb.