VeriFone 1619-20XPL ユーザーズマニュアル

ページ / 37
 
 
CONFIDENTIAL 
Version A 
Page 30 of 37 
MasterCard® PayPass™ Contactless Transit Pilots 
Installation Guide 
 
NOTE PLEASE ENSURE THAT THE POWER CABLE IS NOT PLUGGED INTO THE 3-PIN 
SOCKET BEFORE INSTALLATION COMMENCES. 
 
4.5
 
Installation Process 
The Installation process comprises the following steps. 
4.5.1
 
Hardware Installation 
 
1.
 
Open the CAM door. 
2.
 
Fix the Secura Control Unit Assembly to the shelf within the CAM.  
3.
 
Drill 4 holes on the right door of the CAM using the template supplied. 
4.
 
Fix the contactless card reader assembly to the door and secure with the fixing bolts 
provided. 
5.
 
Attach  the  Secura  to  the  LED  Indicator  Board  Cable  using  the  LED  Board  Cable, 
08828-01-R. 
6.
 
Attach  the  Secura  to  the  Contactless  Reader  using  OTI  Contactless  Reader  Cable, 
08829-01-R. 
7.
 
Attach the Secura to the LAN cable. 
8.
 
Attach  the  Secura  to  the  turnstile  release  using  the  Solenoid  Cable,  08827-02-R. 
Ensure that the terminals are connected red to red and black to black. 
9.
 
Ensure that all connection points are fully home. 
4.5.2
 
Functional Test 
1.
 
Plug  in  the  power  and  ensure  that  the  Secura  powers  up  correctly  and  the  LEDS 
light up. The Secura display will display a couple of events, namely: 
o
 
Event 20 – power up 
o
 
Event 23 – In Service 
2.
 
The terminal may attempt to contact MMS at this point, to pick up its configuration. 
This will take a few moments to complete. 
3.
 
A number  of  self-tests can then be  carried out using  the key board  functions of the 
Secura. Refer to section 5 for full details of the available functions. 
a.
 
Select function 37 on the keyboard, press 3, 7 then ENT. This will switch on 
the green LEDs 
b.
 
Select function 38 on the keyboard, press 3, 8 then ENT. This will switch on 
the green LEDs 
c.
 
Select  function  26  on  the  keyboard,  press  2,  6  then  ENT.  This  will  exercise 
the green LEDs, the red LEDS and fire a turnstile release (solenoid) pulse. 
d.
 
If  the  terminal  has  not  contacted  MMS  when  power  was  applied,  perform  a 
communications test to ensure that connectivity with MMS can be established 
satisfactorily. Do this by selecting function 46. 
e.
 
Test  that  communications  with  the  Transit  Payment  Platform  Authorisation 
Server can be established by performing function 44.