4.
Functions
(1) Standby mode
Except the time of data transmission and reception, the equipment operates in
standby mode, in order to prevent consumption of the battery.
(2) Transmit mode
The equipment has the following transmission modes. (Setting change can be
performed about ①~④ by LF equipment. Please confirm to a system administrator
about an actual setting mode.)
①
Fixed time
The equipment transmits a data at set-up interval.
②
Vibration detection
The equipment transmits a data when the equipment detects a vibration. If a
detection interval is set, the equipment detects a vibration at set-up interval and
transmits a data.
③
Push-button switch
The equipment starts transmission when the push-button switch is pushed 0.5
seconds or more. It becomes continuation transmission in this state, and the LED
blinks in order to indicate that the push-button switch was pushed. All other
functions will be invalid.
Transmission interval: about 1 second at first to 10th
about 2.5 seconds at 11th and after
④
Push-button switch transmission release
In case of continuation transmission operation in ③, continuation transmission
can be terminated by pushing the button again. In that case, transmission which
tells that this continuation transmission was completed is performed at the time of
an end.
⑤
Battery capacity is empty
The equipment checks remaining battery capacity (battery voltage) at once in
every 24 hours. The results are judged on a scale of 0 to 3 shown below, and in case
of “CODE: 0”, the equipment performs transmission to tell that the battery is being
discharged.
CODE:3 (full) → CODE:2 → CODE:1 → CODE:0 (empty)
⑥
Safety switch
Stop the transmission by ON→OFF. It uses to stop transmission compulsory. It
becomes the normal mode by OFF→ON and starts operation according to a preset
value. In that case, the equipment performs the transmission to tell that the switch
was canceled.